Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES
Choose a sub category:
BREAKER BOXES MOBILE HOME LOAD CENTERS SPA PANEL BOXES
GENERATOR PANEL BOXES SAFETY SWITCHES DISCONNECT BOXES
METER BASES PANEL BOX ACCESSORIES UTILITY POWER OUTLETS
Sort By:
1 2 3 ... 7
Cutler Hammer BRFPP Filler Plate GROUND BAR 7 HOLE CONSUMER PK GE THFILLER Rectangle Filler Plate
Plastic (snap-in) for type BR 1" space. May also be used with 400 amp and 600 amp load centers. For grounding copper or aluminum terminals in a GE load center. Offers 4 small holes for 14 - 8 AWG copper or 12 - 8 AWG aluminum terminals and 3 large holes for 14 - 4 AWG copper or 12 - 4 AWG aluminum terminals. UL Listed and ANSI Certified. 6.875" height x 2.875" width x 0.5" depth, .105 lb. Covers circuit breaker knock outs that have been removed in error.  Two 1" and two 1/2" plates.
LUG KIT NO6-2/0 NEUTRAL/GROUND GROUND BAR 24 HOLE PM-GOLD PK Square D QOFPCP Filler Plate
For use with wire range 6-2/0. Can be mounted on any neutral or ground position by simply removing the termination screw. UL Listed. 2.875" height x .75" width x  6.875" depth, .07 lb. Used for additional grounding as required by local code. Compatible with most load center enclosures. Fits solid or stranded 4 - 14 copper wire and 10 - 12 aluminum wire. Includes mounting screws. UL Listed and ANSI Certified. 11" height x 3.5" width x 0.5" depth, .304 lb. Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified.
Square D PK7GTACP Ground Bar Kits Square D QO70AN Auxiliary Neutral Lug Kit Square D HOMFPCP Filler Plate
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Made for QO load centers. Field installed for number 12 - 2 Al or number 14 - 4 Cu wire. QO accessories can only be used with QO load centers. Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified.
Schneider PK3GTA-1CP Ground Bar Kit Square D ACPCP Closing Plate Square D PK4GTACP Ground Bar Kits
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Used for sealing off a hub opening when a service feed originates underground. The plate is compatible with A-type openings and can be used on outdoor devices that utilize a 4-hole mounting pattern. Use for A-size hub opening for Square D metering equipment. UL and CSA Listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed.
Square D HOM100AN Neutral Lug Kit Square D PK15GTACP Ground Bar Kits Cutler-Hammer GBK10P Ground Bar Kits
Breaker box neutral lug is designed for Homeline load centers. It works with number 1 - 1/0 copper and aluminum wire. UL Listed, ANSI Certified. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Bar wire holes are suitable for (1) #14-4 or up to (3) #14-10 aluminum or copper wire. Multiple wires in a single hole must be of the same size and material. Distance between mounting holes is 1-3/4". NOTE: Consult local code for correct application of ground bar kit for service entrance equipment. Kit contains one ground bar and two #10-32 x 5/8" self-threading screws. UL Listed.
Siemens EC2GB152 Ground Bar Kit With Terminal 2/0 Lug Square D PK23GTACP Ground Bar Kits Siemens EC38595 Closure Plate
For equipment grounding provision. #14 to 4 AWG, 60/75 degree Celsius, Cu/A1. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Fits any meter socket application where a closure plate is needed.
Cutler-Hammer GBK14P Ground Bar Kits GE Electrical TFN60RCP AC Disconnect Switches Schneider PK9GTACP Ground Bar Kit
Bar wire holes are suitable for (1) #14-4 or up to (3) #14-10 aluminum or copper wire. Multiple wires in a single hole must be of the same size and material. Distance between mounting holes is 1-3/4". NOTE: Consult local code for correct application of ground bar kit for service entrance equipment. Kit contains one ground bar and two #10-32 x 5/8" self-threading screws. UL Listed. Steel enclosure. 2 pole, 3 wire, 240 volt AC, rated 10 HP. For central air conditioner. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. 4-3/4" x 7-1/2" x 2". UL1429 enclosure pullout switch, UL Listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed.
Square D PK12GTACP Ground Bar Kits Siemens EC3GB302 Ground Bar Kit With Terminal 2/0 Lug Siemens Energy ECGB10 Ground Bar Kits
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. For equipment grounding provision. #14 to 4 AWG, 60/75 degree Celsius, Cu/A1. For equipment grounding provision. #14 to 4 AWG, 60/75 degree Celsius, Cu/A1.
Eaton DPU222RP Type ACD Non-Fusible Pullout Disconnect Switch Schneider PK18GTACP Ground Bar Kit Cutler Hammer GBK21P Ground Bar Kit
Single phase, 2 pole, 2 wire, 240 volt AC, galvanized steel enclosure with molded case switch. Rated 3 HP at 120 volt, 10 HP at 240 volt. For bottom entry and exit only. Heavy duty, high strength enclosure with welded and riveted construction. Swing-up cover remains in place when in open position, and includes provision for padlocking. 10,000 AIR. When pullout is in off position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.96-3258-4 pullout head replacement sold separately. #14-3 AWG wire range. 5-3/8" x 8-3/4" x 3-1/8". UL Listed file No.E5239. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Bar wire holes are suitable for (1) #14-4 or up to (3) #14-10 aluminum or copper wire. Multiple wires in a single hole must be of the same size and material. Distance between mounting holes is 1-3/4". NOTE: Consult local code for correct application of ground bar kit for service entrance equipment. Kit contains one ground bar and two #10-32 x 5/8" self-threading screws. UL Listed.
Siemens ECLK2125 Sub-Feed Lug Kit Siemens Energy WN2060U AC Disconnect Switches Cutler-Hammer DPF221RP AC Disconnect Switches
Sub feed lug kit. 125 amp. 2 pole. Lugs to sub feed to another panel. Single phase, 2 pole, 2 wire, 240 volt, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32" x 7-5/16" x 2-7/32". UL Listed. Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of  #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". NEMA 3R, rainproof. UL Listed, CSA Approved.
   
 
1 2 3 ... 7